Electronic Case Report Form (eCRF) Development
Intrinsic Imaging provides electronic case report form (eCRF) development, combining physician-led design, programmed data checks, and study-specific validation to capture every image assessment completely and consistently. Each eCRF is built for one study and records the measurements and determinations that its imaging charter requires.
At Intrinsic Imaging, our eCRF development team brings together the physicians who define the assessment with our technology and data specialists, who configure and test the form. Physicians decide what a reviewer must record and in what order, and specialists translate those decisions into fields, rules, and calculations, producing a form that follows the reviewer’s clinical reasoning.
Intrinsic Imaging supports eCRFs for qualitative and quantitative assessments, including lesion measurements, categorical grading, response determination, and adjudication, and can apply more than one set of criteria within a single study. Our teams work closely with sponsors from imaging charter development through database lock to specify the form, validate it before use, and control every later change.
By combining clinical design with programmed checks and documented testing, Intrinsic Imaging helps sponsors obtain complete assessment data that are ready for analysis, reduce queries to reviewers, and trace each reported value to the reviewer who entered it.
Designed From the Imaging Charter
Intrinsic Imaging derives each eCRF from the assessment method in the imaging charter, so that every field corresponds to a measurement, a finding, or a determination the imaging charter defines. FDA’s guidance on clinical trial imaging endpoints encourages sponsors to attach an example case report form to the imaging charter and to mark the items that will be transferred for analysis. Intrinsic Imaging prepares the eCRF specification alongside the imaging charter, giving the sponsor’s clinical and statistical teams an early view of the data they will receive.
Each field is defined with its permitted values, units, and precision and is mapped to the corresponding variable in the data transfer specification. Defining the form and the transfer together allows Intrinsic Imaging to deliver assessment data in the structure the sponsor’s database expects.
Programmed Controls for Complete, Consistent Assessments
Intrinsic Imaging configures each eCRF to present only the fields relevant to the reviewer’s earlier answers, to require the entries the imaging charter makes mandatory, and to reject values outside defined limits. Calculations specified in the imaging charter, such as sums of lesion diameters and percent change from baseline, are performed by the form. These controls remove common sources of omission and arithmetic error before an assessment is signed.
Each completed eCRF is signed electronically and locked within Intrinsic Imaging’s validated, 21 CFR Part 11 compliant system. Role-based access limits each reviewer to assigned cases, and the audit trail records who entered or changed a value and when. Intrinsic Imaging therefore preserves the original assessment in reviewable form after adjudication or a later correction.
Validated Before Use
Intrinsic Imaging tests each eCRF against its specification before release, including its conditional logic, data checks, calculations, and exported values, as part of the study’s software validation. User acceptance testing confirms that the form works as reviewers will use it, and the sponsor reviews the results before the first assessment. When an amendment changes the assessment during the clinical trial, the form is revised under change control and retested before reviewers use the new version.
Frequently Asked Questions
What do Intrinsic Imaging’s press releases document?
When does Intrinsic Imaging’s turnaround clock start and stop?